The explosion-proof enclosure for safety light curtains is designed and approved for use in hazardous locations according ATEX for gas: II 2 G Ex d IIB T6 Gb, for dust: II 2 D Ex tb IIIC T56°C Db. NFPA 70/NEC 500, Class I, Div. 1, groups C and D, Class II, Div. 1, groups E, F and G and Class III, Div. 1. The enclosure is compatible with a variety of SICK safety light curtains to fit multiple applications including paint booths, granaries, chemical processing and many others. The explosion-proof enclosure and safety light curtains have been tested together and are UL listed to give you the peace of mind that your safety solution meets the necessary safety and regulatory standards.
At a glance:
- ATEX for gas: II 2 G Ex db IIB T6
- ATEX for dust: II 2 D Ex tb IIIC T56°C Db IP6X
- NFPA 70/NEC 500 Class I, Div. 1, Groups C and D
- NFPA 70/NEC 500 Class II, Div. 1, Groups E, F and G
- NFPA 70/NEC 500 Class III, Div. 1
- Available in protective field heights of 600 mm, 900 mm and 1,200 mm
- Resolution of 30 mm
- Scanning range of 16 m
Temperature range | 0 °C ... +55 °C |
Scanning Range | 16 m |
Protection (IP) | 65, 66 |
Optical Safety Device |
|
Detection range | 16-21 m |