The safety light curtains ILVT are electrosensitive protective devices

blanking of obstacles with reliable safety

11 blanking features easy to program

integrated switching unit: contactor control and restart interlock

extremely short reaction times

protective field up to 1,9 m high, range 20 m

Optical Safety Device
  • Safety Light Curtain
  • Safety Scanner
Protection (IP) 65
Operating range 1.9-20 m
Configuration through-beam
Type of beam multibeam
Other characteristics body protection

Type 2 safety light curtain ILVT Alternatives

See all 216 Safety Scanners
Autonics Type 4 safety light curtain SFLA Series

5/5 (1)

The SFLA series safety light curtains are installed in potentially dangerous or hazardous areas to safeguard personnel from injury. The light curtains feature proven technology from Autonics area sensors and mapping sensors. The light curtains are built to meet internationally safety standards and regulations. Various detection models (finger/hand/hand-body detection) and safety functions are available for diverse applications. The dedicated software atLightCurtain allows real-time status monitoring user settings such as automatic muting/blanking area functions.
BANNER Type 4 safety light curtain EZ-SCREEN LS SERIES
Scanning range 12m

5/5 (1)

BANNER's EZ-SCREEN LS light curtains are a reliable and easy-to-use safety device designed for machine safeguarding in challenging manufacturing and packaging environments. With three resolutions available, ranging from 14 mm to 40 mm, and a range of up to 12 m, these light curtains provide end-to-end sensing with no blind zones. The aluminum housing and metal end caps protect each emitter and receiver against impacts, while highly visible alignment indicators and intuitive diagnostics make setup and troubleshooting a breeze.The EZ-SCREEN LS system requires no PC software or DIP switches for quick and easy configuration. The dual scan technology ensures high immunity to EMI, RFI, ambient light, weld flash, and strobe light. The no blind zone design eliminates gaps in detection, while the system can cascade up to four systems of any length, resolution, and number of beams.These light curtains are certified to Type 4 per IEC 61946, Category 4 PLe per EN ISO13849.1, and SIL3/SILCL3 per IEC 61508/IEC 62061, exceeding OSHA/ANSI control reliability requirements. The EZ-SCREEN LS pair model numbers come with an LS receiver, LS emitter, end-cap bracket kit, and center-mount bracket kit, making them a reliable choice for a range of manufacturing and packaging applications.
BANNER Type 2 Series
No reviews yet.
30 mm Resolution Type 2 Safety Light Curtains Compact optical safeguarding solution is designed for lower-risk applications where risk of injury is limited but some guarding is necessary.Designed for lower-risk applications such as bump or bruise, knock-down, trapping but not crushing, or minor cuts and abrasionsFeatures simple, two-piece integrated system with no control boxDetects narrow objects, such as a hand or ankleOffered with 30 mm resolution and 15 m rangeProvides economical, compact optical safeguardingMeets Type 2 requirements per IEC61496-1/-2 and Category 2 per EN954-1Available in trip (auto reset) or latch (manual reset) models
Autonics Safety light curtain SFL Series
No reviews yet.
The SFL series safety light curtains are installed in potentially dangerous or hazardous areas to safeguard personnel from injury. The light curtains feature proven technology from Autonics area sensors and mapping sensors. The light curtains are built to meet internationally safety standards and regulations. Various detection models (finger/hand/hand-body detection) and safety functions are available for diverse applications.
BANNER Safety Light Curtains
No reviews yet.
Safety light curtains protect personnel from injury and machines from damage by creating a sensing screen that guards machine access points and perimeters. Banner offers intuitive, easy-to-use safety light curtains for a wide variety of safety applications. Type 4 safety light curtains protect personnel from injury and machines from damage by guarding points of operation, access, areas and perimeters. Type 2 safety light curtains are a cost-effective light curtain safety solution for guarding lower-risk applications, where the result of an accident is only a slight injury.
Rockwell Automation 445L Guardshield™ POC Type 4 Micro 400 safety light curtains
No reviews yet.
Our Bulletin 445L Guardshield™ POC Type 4 Micro 400 safety light curtains are economical three-box safety light curtains in a small housing. Designed for use in benign industrial environments (IP54), this light-duty system is targeted to the semi-conductor, micro electronic and small assembly machine markets. We also offer these light curtains in cascadable configurations and in IP69K enclosures. The Micro 400 requires a dedicated controller such as the MSR41 for ON/OFF applications or the MSR42 for advanced safety functionality. Compact Type 4, SIL 3, PLE safety light curtainsM12 connector on 20 in. pigtailsMinimal dead space of optic headsTypical applications for the POC Type 4 GuardShield™ Micro 400 Light Curtains include:Food and beverage (IP69K)Light assembly machines/equipmentMicro-electronicsPharmaceuticalSemi-conductor
PILZ Safety light curtain PSENopt
No reviews yet.
The safety light curtain PSENopt, also referred to as a light barrier, can be used in all areas of industry where a barrier-free safety concept is to be implemented. Thanks to their compact dimensions and ease of installation, the safety light curtains enable an ergonomic work environment. This is the case, for example, when operator intervention is required as part of each cycle, such as insertion work, or the infeed and outfeed of material. You can choose between Type 2 and Type 4 safety light curtains in accordance with EN IEC 61496-1/-2, versions for finger, hand and body protection, in lengths from 15 cm to 180 cm. In addition to the Basic light curtains, all Advanced light curtains offer expanded functionalities such as muting, blanking and cascading. Slimline safety light curtains PSENopt slim can be used for space-critical applications. Accessories range from deviating mirrors, protective columns for shock, collision and vibration protection, protective IP6K9K housing through to test rods. You’ll find the required cable, connector and adapter accessories under Connection technology. High productivity with the safety light curtains PSENoptProtected fields and detection capability can be set up to be process-orientedHigher productivity due to reduced access timesRapid and simple assembly, installation and commissioningUser-friendly diagnostics thanks to built-in LEDs to reduce down timesComprehensive portfolio including accessories – ideal in combination with safe control technology from Pilz For every discipline – additional benefits of the safety light curtains PSENopt Advanced Simple configuration and commissioning with the PSENopt ConfiguratorThree functionalities in one safety light curtain: muting, blanking and cascadingIncreased safety as there are no dead zonesFlexible installation thanks to coding Small safety light curtains, high level of safety – additional benefits of the PSENopt slimNarrow design saves space and costsIncreased safety as there are no dead zonesEffective protection against encroachment into and behind the protected area thanks to the cascading function
Fiessler Type 2 safety light curtain ILCT series
No reviews yet.
TLCT/ILCT safety light curtains each comprise two components: Light transmitter and light receiver. The clearance between these two components and the installation height determine the width and height of the protective field (Figure 5/1). Modular design permits realization of protective field heights ranging from 100 mm to 1500 mm in 100-mm steps. The transmitter generates infrared light beams in rapid pulses. These parallel light beams are analyzed by two single-chip controllers in the transmitter. The beam spacing determines the resolution. If an object enters the protective field, i.e. if at least one light beam is interrupted, the receiver's two outputs stop the machine or prevent it from starting, thus avoiding hazards. In the restart with interlock operating mode, the machine can only be restarted by means of the start button once the protective field has been cleared again.
Fiessler Type 2 safety light curtain TLCT series
No reviews yet.
TLCT/ILCT safety light curtains each comprise two components: Light transmitter and light receiver. The clearance between these two components and the installation height determine the width and height of the protective field (Figure 5/1). Modular design permits realization of protective field heights ranging from 100 mm to 1500 mm in 100-mm steps. The transmitter generates infrared light beams in rapid pulses. These parallel light beams are analyzed by two single-chip controllers in the transmitter. The beam spacing determines the resolution. If an object enters the protective field, i.e. if at least one light beam is interrupted, the receiver's two outputs stop the machine or prevent it from starting, thus avoiding hazards. In the restart with interlock operating mode, the machine can only be restarted by means of the start button once the protective field has been cleared again.
Rockwell Automation 450L GuardShield PAC Safety Light Curtains
No reviews yet.
Our 450L GuardShield™ PAC Safety Light Curtains help protect personnel from hazardous machinery. These light curtains are designed for whole-body detection and are typically positioned around an area or in front of a machine process entry or exit area that poses a moderate to high risk of operator injury. Our GuardShield safety light curtains are unlike traditional safety light curtains, which are based on separate transmitter and receiver units. Patented technology allows each transceiver to be used as a transmitter or receiver via an innovative plug-in module. Like the other advanced products in the 450L GuardShield line, the PAC versions also feature integrated laser alignment, cascading, blanking, and integrated muting. Features a compact design 30 mm x 30 mm (1.18 in. x 1.18 in.)Includes Integrated Laser Alignment System (ILAS), plug-in DIP switches and integrated muting option available for easy installation and configurationOffers innovative plug-in modules (available separately) which enable basic (ON/OFF)Provides cascading plug-ins for serial connection of safety light curtainsCovers a wide range of protection heights 150 mm, 600 mm, 900 mm or 1050 mm and available in 1-, 2-, 3-, or 4-beam models respectivelyOffers a versatile mounting options for enhanced application flexibility
Fiessler Type 4 safety light curtain ULCT series
No reviews yet.
ULCT/BLCT safety light curtains each comprise two components: Light transmitter and light receiver. The clearance between these two components and the installation height determine the width and height of the protective field (Figure 5/1). Modular design permits realization of protective field heights ranging from 100 mm to 1500 mm in 100-mm steps. The transmitter generates infrared light beams in rapid pulses. These parallel light beams are analyzed by two single-chip controllers in the transmitter. The beam spacing determines the resolution. If an object enters the protective field, i.e. if at least one light beam is interrupted, the receiver's two outputs stop the machine or prevent it from starting, thus avoiding hazards. In the restart with interlock operating mode, the machine can only be restarted by means of the start button once the protective field has been cleared again.